Category 1 nonfriable asbestos-containing material (AMC) ✔✔means asbestoscontaining packages, gaskets, resilient floor covering, and asphalt roofing...Category 1 nonfriable asbestos-containing material (AMC) ✔✔means asbestoscontaining packages, gaskets, resilient floor covering, and asphalt roofing products
containing more than 1 percent asbestos as determined using the method specified in
appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy
Category II nonfiriable AMC ✔✔means any material, excluding Category I nonfirable
AMC, containing more than 1 percent asbestos as determined using the method
specified in appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light
Microscopy that , when dry, cannot be crumbled, pulverized, or reduced to powder by
hand pressure
Demolition ✔✔means the wrecking of tacking out of any load-supporting structural
member of a facility together with any related handling operations or the international
burning of any facility
Friable asbestos material ✔✔means any material containing more than 1 percent
asbestos as determined using the method specified in appendix E, subpart E, 40 CRF
part 763, section 1, Polarized Light Microscopy that , when dry, can be crumbled,
pulverized, or reduced to powder by hand pressure. If the asbestos content is less than
10 percent as determined by a method other than point counting by polarized light
microscopy (PLM), verify the asbestos content by point counting using PLM.
Regulated asbestos-containing material (RAMC) ✔✔means (a) Friable asbestos
material, (b) Category I nonfriable AMC that has become friable, (c) Category I
nonfirbale AMC that will be or has been subjected to sanding, grinding, cutting, or
abrading, or (d) Category II Nonfirable ACM that has become crumbled, pulverized, or
recorded, or reduced to powder by the forces expected to act on the material in the
course of demolition or renovation operations regulated by this subpart
Renovations ✔✔means altering a facility or one or more facility components in any way,
including the stripping or removal of RAMC from a facility component. Operations in
which load-supporting structural members are wrecked or taken out of demolitions.
Visible emissions ✔✔means any emissions, which are visually detectable with out the
help of instruments, coming form RAMC or asbestos-containing waste material, or form
any asbestos milling, manufacturing, or fabricating operations. This does not include
condensed, uncombined water vapor
61.145 Standard for demolition and renovation (a) 1 (i) ✔✔At least 80 linear meters
(260 linear feet) on pipes or at least 15 square meters (160 square feet) on another
facility components
61.145 Standard for demolition and renovation (a) 1 (ii) ✔✔At least 1 cubic meter (